SC7130-CC Per IPC-CC-830C Independent Lab Certification Results
TestProcedure-MethodRequirements/CommentsResults
Coating Thickness (Spray and Dip Coating Method)Thickness measurementThickness: Min. 12.5µm; Max. 50µm in meeting all requirements for “Parylene Classification” of performance. All other classes need heavier coating.PASS
Visual inspectionOn glass plate under white and UV lightCoating must have uniform appearance and consistencyPASS
FluorescenceOn glass plate under black (UV) lightCoating must fluoresce under UV black light (typical wavelength 365nm)PASS
Fungus resistanceIPC-TM-650 section 2.6.1.1 on glass plateNot attacked by biological growth
UL 94 test strip for flammabilityUL 94 HBMust meet a minimum horizontal burning test PASS; V-0 Self-Extinguishing
FlexibilityIPC-TM-650 section 2.4.5.1 on tin panelNo evidence of cracking or crazing of the cured coatingPASS
Dielectric Withstanding VoltageIPC-TM-650 sec. 2.5.7.1 on IPC-B-25A Test BoardNo disruptive discharge, sparkover, or breakdown.  @1500VAC, Max 10 uA leakage rate; Pattern D insulation resistance >10¹²ΩPASS
Moisture and Insulation ResistanceIPC-TM-650 section 2.6.3.4 on IPC-B-25A

 

Minimum 500MΩ for ER and 5GΩ for all other types after exposure to humidity within 1-2hours of exposure; Insulation resistance post moisture exposure: >10¹¹Ω = before exposure (No Degradation)PASS, Meets Requirements for “Parylene Type”
Thermal ShockIPC-TM-650 section 2.6.7.1 on IPC-B-25AAppearance and Dielectric Withstand Voltage after testing must meet the above-mentioned passing levelsPASS
Temperature and Humidity AgingIPC-TM-650 sect. 2.6.11.1 on ‘‘Y Panel” test couponNo evidence of softening, tack, cracking, loss of adhesion, or reversionPASS
New Type of Conformal Coating from AI Technology, Inc.
  • SC7130-CC is a new class of thin conformal coating with molecular structure of fluorinated polymer for hydrophobic and moisture barrier
  • Designed for low cost spray-dip-brush coating methods to achieve 12.5-50µm thickness
  • The strong and tight molecular stability is engineered for extreme conditions including salt-fog, salt-water, acid rain, and corrosive environments
  • This Parylene replacement conformal coating has been proven to outperform all traditional conformal coating in more stringent Radio Technical Commission for Aeronautics (RTCA DO 160) applications